# Drainage or sewage pump: how to choose

> How a drainage pump differs from a sewage pump, what particle sizes they handle, when you need a grinder, how to work out the head and why a pump must never sit directly on silt.

Web page: https://watertrade.com.ua/en/articles/article/drenazhnyj-ili-fekalnyj-nasos · Other languages: [UA](https://watertrade.com.ua/articles/article/drenazhnyj-ili-fekalnyj-nasos.md), [RU](https://watertrade.com.ua/ru/articles/article/drenazhnyj-ili-fekalnyj-nasos.md)

*November 23, 2026*

![Diagram: drainage pump with a float in a basement sump, grinder sewage pump in a septic tank, discharge pipes with check valves](https://watertrade.com.ua/uploads/articles/drainage-fecal.jpg)

Submersible pumps for dirty water look alike but are built for different jobs. A drainage pump will empty a basement after a downpour but cannot handle sewage, while a sewage pump moves waste water but is overkill and expensive for clean water. The choice starts with one question: what exactly will be in the water.

## What the diagram shows

1 — a drainage pump in a basement sump, 2 — the float that switches the pump on and off, 3 — a grinder sewage pump in a septic tank, 4 — a discharge pipe with a check valve.

## Drainage pump

For water without large solids: a flooded basement or cellar, a sump, an excavation, a pool, a well before cleaning. Clean water models pass particles up to 5–10 mm, dirty water models up to 25–35 mm (sand, silt, small stones). Most handle water up to 35–40 °C. The body is plastic or stainless steel.

## Sewage pump

For waste water with fibres and solids up to 40–50 mm: septic tanks, cesspits, basement sewage stations. The body is usually cast iron, and a vortex impeller does not clog with rags or hair.

- **With a grinder** — a cutting blade shreds the waste so it can be pumped under pressure through a 32–40 mm pipe over a long distance or uphill. Needed when the sewer is higher than the bathroom or far away.
- **Without a grinder** — for pumping into a wide pipe over a short distance.

> Never stand the pump directly on silt or sand — it will suck in dirt and fail quickly. Put a brick or slab underneath, and lower and lift the pump by a rope, not by the cable.

## Sizing by specs

1. **Particle size** — see above: drainage or sewage.
2. **Head**: the vertical lift plus roughly 1 m for every 10 m of horizontal pipe. On the pump curve pick a point where the needed flow is still available at that head.
3. **Flow**: 6–10 m³/h is enough for a basement; excavations and ponds need more.
4. **Float** — for automatic operation. Make sure it has room to move in the sump: for a narrow sump choose a pump with a vertical float or an electronic sensor.
5. Fit a **check valve** on the discharge if the water is lifted high, otherwise it will flow back after the pump stops.

Drainage and sewage pumps are in [drainage pumps](https://watertrade.com.ua/en/catalogue/nasosy/drenaznye-nasosy), separate floats in [float switches](https://watertrade.com.ua/en/catalogue/nasosy/poplavkovye-vyklucateli). Step-by-step basement pumping — see [“How to pump water out of a basement”](https://watertrade.com.ua/en/articles/article/otkachat-vodu-iz-podvala); where to fit a check valve — [here](https://watertrade.com.ua/en/articles/article/obratnyj-klapan).

---

Watertrade · Phone: (093) 917-25-45 · sale@watertrade.com.ua · Site map for language models: https://watertrade.com.ua/en/llms.txt