# Water heater safety valve dripping: causes and fixes

> Why a water heater safety valve drips, when that is normal, how a pressure reducing valve and an expansion vessel solve it, and why the valve must never be plugged.

Web page: https://watertrade.com.ua/en/articles/article/predohranitelnyj-klapan-bojlera-kapaet · Other languages: [UA](https://watertrade.com.ua/articles/article/predohranitelnyj-klapan-bojlera-kapaet.md), [RU](https://watertrade.com.ua/ru/articles/article/predohranitelnyj-klapan-bojlera-kapaet.md)

*November 26, 2026*

![Diagram: pressure reducing valve on the cold supply, hot water expansion vessel, water heater safety valve draining into a tundish](https://watertrade.com.ua/uploads/articles/boiler-valve-drip.jpg)

The valve on the cold inlet of the water heater drips — some people put a jar under it, others want to plug it. The first is a nuisance, the second is dangerous. First work out whether the valve is simply doing its job or pointing to a problem you can fix.

## What the diagram shows

1 — a pressure reducing valve on the cold supply, 2 — the water heater safety valve, 3 — the valve discharge to the drain through a tundish, 4 — an expansion vessel for hot water.

## When dripping is normal

Water expands as it heats: an 80-litre heater warming from 10 to 70 °C gains about 2 litres. While no hot water is drawn off, that volume has nowhere to go, so the valve releases it — a few drops during heating. That is the valve working, not failing.

## When it is a problem

- **It runs constantly, even when the heater is not heating** — mains pressure is above the valve setting (usually 6–8 bar), or scale and sand keep the valve from closing.
- **It dumps a lot of water every heating cycle** — high inlet pressure; mains pressure often rises at night.
- **It never drips** — the valve may have seized. This is the most dangerous case.

> Never plug the valve or fit a stop valve between it and the heater. Without relief, pressure during heating can burst the tank.

## What to do

1. **Measure the inlet pressure** with a gauge, ideally at night. Above 4–5 bar you need a **pressure reducing valve** (1) in front of the heater, set to 3–4 bar.
2. **Fit a hot water expansion vessel** (4) — white or blue, rated for potable water, about 10 % of the heater volume. It takes up the expanded water and the valve stops dripping during heating.
3. **Test the valve itself**: once a month lift the lever for a couple of seconds — water should flow and stop when released. If it keeps running or the lever is stuck, replace the valve; it is inexpensive.
4. **Pipe the discharge** (3) to the drain through a tundish with an air gap — the water goes away without smells.

6–10 bar valves are in [water heater safety valves](https://watertrade.com.ua/en/catalogue/zapornaa-armatura/predohranitelnye-klapany/products/predohranitelnye-klapany-dlya-bojlera), reducers in [pressure reducing valves](https://watertrade.com.ua/en/catalogue/zapornaa-armatura/reduktory-davlenia). The full layout is in [“How to connect a water heater”](https://watertrade.com.ua/en/articles/article/podklyuchenie-bojlera); setting a reducer — [here](https://watertrade.com.ua/en/articles/article/reduktor-davleniya-vody).

---