# Pressure switch does not turn the pump off: causes and fixes

> Why a pump runs non-stop and the pressure switch never cuts it out: the pump cannot reach the pressure, the switch is set above the pump’s limit, a blocked inlet, burnt contacts. How to find the cause with a gauge.

Web page: https://watertrade.com.ua/en/articles/article/rele-davleniya-ne-otklyuchaet-nasos · Other languages: [UA](https://watertrade.com.ua/articles/article/rele-davleniya-ne-otklyuchaet-nasos.md), [RU](https://watertrade.com.ua/ru/articles/article/rele-davleniya-ne-otklyuchaet-nasos.md)

*November 17, 2026*

![Diagram: booster set, pressure switch with the cover off showing two springs, the switch inlet, a gauge on the pipe and the pressure tank](https://watertrade.com.ua/uploads/articles/pressure-switch-not-off.jpg)

All taps are closed, yet the pump hums on and never stops. Do not leave it like that even for half an hour: the pump overheats, and if the well runs dry it will burn out from dry running. The cause can almost always be found in 10–15 minutes — all you need is a pressure gauge and a little attention.

## What the diagram shows

1 — the pressure switch with its cover off, 2 — the pressure gauge, 3 — the pressure tank, 4 — the switch inlet connection.

## First, watch the gauge

Close every tap and watch the gauge (2) while the pump runs. There are two possibilities, each with its own causes.

## Pressure rises but never reaches cut-out

The needle climbs and stops at, say, 2.6 bar while the switch is set to 3. The pump simply cannot deliver more:

- **The switch is set above the pump’s capability.** A common mistake after “adjusting” the large nut. Lower the cut-out so it is 0.3–0.5 bar below the maximum the pump holds on the gauge.
- **Air or a suction leak** — the water level has dropped, the foot valve leaks or a joint is not tight. The pump moves water full of bubbles and cannot build pressure.
- **A clogged filter** or suction strainer.
- **A leak** downstream: a running toilet, a dripping tap, a burst buried pipe.
- **A worn impeller** or low mains voltage — the pump weakens over time.

## Pressure reaches cut-out, but the pump keeps running

Then the switch (1) itself is not operating:

- **A blocked inlet** (4) — rust and sand have plugged the opening, so the switch cannot sense pressure. Remove the switch and clean the inlet.
- **Burnt or welded contacts** — signs of scorching are visible.
- **A ruptured diaphragm** — water seeps from under the cover.

In the last two cases replace the switch; it is inexpensive.

> Unplug the pump before removing the switch cover: there is 220 V inside. To stop this happening again, fit dry-run protection — it switches the pump off if the source runs dry.

## Setting it again

The large spring sets the cut-in pressure, the small one the difference between cut-in and cut-out (usually 1–1.5 bar). Step-by-step adjustment is in [“Setting a pressure switch”](https://watertrade.com.ua/en/articles/article/nastrojka-rele-davleniya). If the pump instead starts too often — [6 reasons](https://watertrade.com.ua/en/articles/article/nasos-chasto-vklyuchaetsya); if it runs but does not pump — [here](https://watertrade.com.ua/en/articles/article/nasos-ne-kachaet-vodu).

Switches and controls are in [pump controls](https://watertrade.com.ua/en/catalogue/nasosy/avtomatika-dla-nasosov), gauges in [pressure gauges](https://watertrade.com.ua/en/catalogue/kontrolno-izmeritelnye-pribory/manometry-i-termometry/products/manometry), ready-made sets in [booster sets](https://watertrade.com.ua/en/catalogue/nasosy/nasosnye-stancii/products/nasosnye-stancii-24-l).

---