# Thermostatic radiator head: how it works and how to choose

> How a thermostatic head holds room temperature, what the scale numbers mean, how to match it to the valve, when you need a remote sensor and why it must not be hidden behind a curtain.

Web page: https://watertrade.com.ua/en/articles/article/termogolovka-na-radiator · Other languages: [UA](https://watertrade.com.ua/articles/article/termogolovka-na-radiator.md), [RU](https://watertrade.com.ua/ru/articles/article/termogolovka-na-radiator.md)

*November 27, 2026*

![Diagram: radiator under a window, thermostatic head on the flow valve, lockshield valve on the return and a remote sensor on the wall](https://watertrade.com.ua/uploads/articles/thermo-head.jpg)

Without a thermostatic head a radiator always runs flat out: on a sunny day or with the oven on the room overheats and the heat escapes through an open window. A thermostatic head closes the water flow by itself when the room is warm and opens it again when it cools. On gas this brings noticeable savings, and rooms stay more even.

## What the diagram shows

1 — the thermostatic head, 2 — the thermostatic valve on the flow, 3 — the lockshield valve on the return, 4 — a remote sensor.

## How it works

Inside the head is a bellows filled with liquid, gas or wax. As the air warms, the filling expands and pushes the valve pin, closing the water flow; as it cools, the pin comes back out. No electricity is needed. The numbers on the scale are not degrees: usually “1” ≈ 12 °C, “3” ≈ 20 °C, “5” ≈ 28 °C — check the head’s manual for exact values.

## Choosing

- **Match the valve.** The head fits a thermostatic valve (2) — an ordinary ball valve will not do. The most common connection is an M30×1.5 thread; some brands use their own, which needs an adapter.
- **One-pipe systems** need a high-flow valve, otherwise the far radiators will be underheated.
- **Range.** Standard for living rooms; for garages and storerooms there are frost-protection models (they hold about 6–8 °C).
- **An electronic head** adds a schedule: lower at night and during the day while nobody is home.

> Mount the head horizontally and do not cover it with curtains, radiator covers or furniture, otherwise it senses the warm air around the radiator and closes too early. If it cannot be kept clear, choose a head with a remote sensor (4) on the wall.

## Fitting

1. Fit the valve on the flow, following the arrow on the body; fit a lockshield valve (3) on the return to balance the radiators.
2. Turn the head to maximum, put it on the valve and tighten the nut by hand.
3. Set the number you want and adjust after a day.

If the house has a boiler room thermostat, do not fit a thermostatic head in that room, or keep it fully open — otherwise the two fight each other.

Heads and valves are in [thermostatic heads for radiators](https://watertrade.com.ua/en/catalogue/otoplenie/radiatornye-krany/products/termogolovki-dlya-radiatorov) and the [radiator valves](https://watertrade.com.ua/en/catalogue/otoplenie/radiatornye-krany) section. Which radiator to choose — see [“Which radiators to choose”](https://watertrade.com.ua/en/articles/article/radiatory-kakie-vybrat); if a radiator is cold at the top — [bleed the air](https://watertrade.com.ua/en/articles/article/vozduh-v-radiatorah).

---

Watertrade · Phone: (093) 917-25-45 · sale@watertrade.com.ua · Site map for language models: https://watertrade.com.ua/en/llms.txt