# How to choose a circulation pump for central heating

> How to size a circulation pump for home heating: what 25-40 and 25-60 mean, how to estimate flow and head, and where and how to fit the pump so it runs quietly for years.

Web page: https://watertrade.com.ua/en/articles/article/vybor-cirkulyacionnogo-nasosa · Other languages: [UA](https://watertrade.com.ua/articles/article/vybor-cirkulyacionnogo-nasosa.md), [RU](https://watertrade.com.ua/ru/articles/article/vybor-cirkulyacionnogo-nasosa.md)

*November 16, 2026*

![Diagram: a boiler, the flow pipe to the radiators, and a circulation pump on the return with ball valves and a strainer in front of it](https://watertrade.com.ua/uploads/articles/circulation-pump.jpg)

A circulation pump moves the heating water through the pipes from the boiler to the radiators and back. Without it, water in a modern system with small-bore pipes barely moves: the far radiators stay cold and the boiler overheats. You can go wrong either way — an undersized pump will not heat the house, while an oversized one makes the pipes noisy and wastes electricity.

## What the diagram shows

1 — the boiler, 2 — the circulation pump on the return, 3 — the radiators, 4 — ball valves and a strainer in front of the pump.

## What the numbers in the name mean

In a marking such as **25-40 180**, the first number is the connection size (25 is for 1" pipe with 1½" union nuts), the second is the maximum head in decimetres (40 means 4 metres), and the third is the body length in millimetres (130 or 180). The body length matters when replacing a pump: the new one should fit in place of the old one without re-plumbing.

## Estimating flow and head

- **Flow** depends on the boiler output. For an ordinary radiator system (about 20 °C between flow and return) allow roughly 0.043 m³/h per kilowatt. A 20 kW boiler needs about 0.9 m³/h.
- **Head** overcomes the resistance of the pipes, fittings and radiators. A house up to 200–250 m² usually needs 4 m (25-40 models); a large house, two storeys with long branches, or underfloor heating — 6 m (25-60).
- Choose a pump whose duty point (flow and head) falls in the middle of its curve, not at the edge.

> Torn between a 25-40 and a 25-60? Take the 25-60 with speed control, or a high-efficiency pump with automatic regulation. You can always turn a pump down, but you cannot make a weak one stronger.

## Standard or high-efficiency

A standard pump runs at one of three speeds set by hand. A high-efficiency (class A) pump adjusts its speed itself: when the thermostatic heads on the radiators close, it reduces power. It costs more, but uses several times less electricity and runs more quietly — it pays for itself within a few seasons.

## How to install it

1. Fit the pump on the return just before the boiler — the water is cooler there and the pump lasts longer. If the boiler or pump instructions allow the flow side, that is fine too.
2. The motor shaft must be horizontal, with the arrow on the body pointing in the direction of flow. Never fit it with the terminal box facing down, as condensation can drip into it.
3. Put [ball valves](https://watertrade.com.ua/en/catalogue/zapornaa-armatura/sarovye-krany) on both sides so the pump can be removed without draining the system, and a [strainer](https://watertrade.com.ua/en/catalogue/filtry-dla-vody/setcatye-filtry) in front of it — otherwise scale and grit will jam the rotor.
4. After filling the system, bleed the air out of the pump through the screw on its end (on models that have one) and only then switch it on.

If the pump hums but the water does not move, or the radiators heat unevenly, there is probably air in the system — see [“Air in radiators: how to bleed it”](https://watertrade.com.ua/en/articles/article/vozduh-v-radiatorah). Choose a model in [circulation pumps](https://watertrade.com.ua/en/catalogue/nasosy/cirkulacionnye-nasosy).

---