All taps are closed, yet the pump hums on and never stops. Do not leave it like that even for half an hour: the pump overheats, and if the well runs dry it will burn out from dry running. The cause can almost always be found in 10–15 minutes — all you need is a pressure gauge and a little attention.
What the diagram shows
1 — the pressure switch with its cover off, 2 — the pressure gauge, 3 — the pressure tank, 4 — the switch inlet connection.
First, watch the gauge
Close every tap and watch the gauge (2) while the pump runs. There are two possibilities, each with its own causes.
Pressure rises but never reaches cut-out
The needle climbs and stops at, say, 2.6 bar while the switch is set to 3. The pump simply cannot deliver more:
- The switch is set above the pump’s capability. A common mistake after “adjusting” the large nut. Lower the cut-out so it is 0.3–0.5 bar below the maximum the pump holds on the gauge.
- Air or a suction leak — the water level has dropped, the foot valve leaks or a joint is not tight. The pump moves water full of bubbles and cannot build pressure.
- A clogged filter or suction strainer.
- A leak downstream: a running toilet, a dripping tap, a burst buried pipe.
- A worn impeller or low mains voltage — the pump weakens over time.
Pressure reaches cut-out, but the pump keeps running
Then the switch (1) itself is not operating:
- A blocked inlet (4) — rust and sand have plugged the opening, so the switch cannot sense pressure. Remove the switch and clean the inlet.
- Burnt or welded contacts — signs of scorching are visible.
- A ruptured diaphragm — water seeps from under the cover.
In the last two cases replace the switch; it is inexpensive.
Setting it again
The large spring sets the cut-in pressure, the small one the difference between cut-in and cut-out (usually 1–1.5 bar). Step-by-step adjustment is in “Setting a pressure switch”. If the pump instead starts too often — 6 reasons; if it runs but does not pump — here.
Switches and controls are in pump controls, gauges in pressure gauges, ready-made sets in booster sets.